Any of these zone types will report to central station if reporting is enabled and the report code in the zone is properly programmed. 24 Hour Auxiliary will sound the keypad, but not the siren and will display zone information. Alarm Panic Buttons by Honeywell are wall or desk mountable and is activated by simply pushing the button, should it be pressed accidentally. 24 Hour Silent will neither sound, nor show zone information on the keypad. 24 Hour Audible will sound both the siren and the keypads and will display the zone information. When programming these zones in the Vista-128BPT, choose a 24 Hour zone type, such as 24 Hour Audible (ZT 07) 24 Hour Silent (ZT 06), or 24 Hour Auxiliary (ZT 08). In the Normally Open circuit, the 2K End of Line Resistor connects across the two terminals at the last panic switch wired in the circuit. A Form C panic could be wired in either of these configurations, at your discretion.Īs you can see, in the Normally Closed configuration, the 2K End of Line Resistor connects to one side of the last panic switch in the circuit, and only one of the zone terminals. Because hardwired zones on the Vista-128BPT require an End of Line Resistor, and we're going to program our zone as a 24 hour alarm, which will activate whether the zone is shorted or opened, and whether the system is armed or disarmed, it doesn't really matter which of these types of switches we use, but I will show both Normally Open, and Normally Closed wiring. The 5802WXT wireless panic button is a great addition to a Honeywell L5100 LYNX Touch wireless alarm control panel. Traditionally, Normally Open switches are used for life safety devices such as smoke detectors, Normally Closed devices are used to protect openings from burglary (a normally closed sensor tied to a door that you want to remain closed just makes logical sense) and Form C devices are typically more expensive than either of the other two options and are usually not required in this situation. The 345 MHz narrow band has very low power and low frequency traffic. The 5800 sensors utilize 345 MHz to transmit data within a nominal range of 200 feet. The first thing you must do, in this instance, is determine which type of panic switch you want to use. The Honeywell Home 5800-Series is the most flexible, convenient and cost effective wireless security in the industry, with over 100 million devices installed trouble-free. Hardwired panic switches can be Normally Open (NO), Normally Closed (NC), or Form C, which means they can be wired either normally open, or normally closed. To answer this question, we must first talk about panic switches in general.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |